A2220
BRESTA Solid Timber System
565
mm
R
w
74
dB
L
nw
39
dB
with floor construction
688
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.217
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2221
BRESTA Solid Timber System
605
mm
R
w
74
dB
L
nw
39
dB
with floor construction
745
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.21
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2222
BRESTA Solid Timber System
625
mm
R
w
75
dB
L
nw
38
dB
with floor construction
755
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.203
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2223
BRESTA Solid Timber System
665
mm
R
w
75
dB
L
nw
38
dB
with floor construction
812
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.196
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2224
BRESTA Solid Timber System
351
mm
R
w
69
dB
L
nw
46
dB
with floor construction and ceiling covering
468
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.331
W/m2 K
C
50-3150
-6
dB
C
I50-2500
2
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2225
BRESTA Solid Timber System
391
mm
R
w
70
dB
L
nw
45
dB
with floor construction and ceiling covering
525
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.314
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2226
BRESTA Solid Timber System
431
mm
R
w
71
dB
L
nw
44
dB
with floor construction and ceiling covering
583
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.298
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2227
BRESTA Solid Timber System
451
mm
R
w
71
dB
L
nw
44
dB
with floor construction and ceiling covering
592
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.285
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2228
BRESTA Solid Timber System
491
mm
R
w
72
dB
L
nw
43
dB
with floor construction and ceiling covering
650
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.272
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2229
BRESTA Solid Timber System
531
mm
R
w
74
dB
L
nw
41
dB
with floor construction and ceiling covering
707
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.26
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2230
BRESTA Solid Timber System
551
mm
R
w
75
dB
L
nw
40
dB
with floor construction and ceiling covering
717
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.25
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2231
BRESTA Solid Timber System
591
mm
R
w
75
dB
L
nw
39
dB
with floor construction and ceiling covering
774
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.24
W/m2 K
C
50-3150
-6
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2232
BRESTA Solid Timber System
458
mm
R
w
80
dB
L
nw
35
dB
with floor construction and ceiling covering
477
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.325
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2233
BRESTA Solid Timber System
498
mm
R
w
81
dB
L
nw
34
dB
with floor construction and ceiling covering
535
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.308
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2234
BRESTA Solid Timber System
538
mm
R
w
81
dB
L
nw
33
dB
with floor construction and ceiling covering
592
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.293
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2235
BRESTA Solid Timber System
558
mm
R
w
82
dB
L
nw
33
dB
with floor construction and ceiling covering
602
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.28
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2236
BRESTA Solid Timber System
598
mm
R
w
83
dB
L
nw
32
dB
with floor construction and ceiling covering
659
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.268
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2237
BRESTA Solid Timber System
638
mm
R
w
84
dB
L
nw
30
dB
with floor construction and ceiling covering
716
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.257
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2238
BRESTA Solid Timber System
658
mm
R
w
84
dB
L
nw
30
dB
with floor construction and ceiling covering
726
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.247
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2239
BRESTA Solid Timber System
698
mm
R
w
85
dB
L
nw
29
dB
with floor construction and ceiling covering
783
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.237
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF